Microwave sensor for contactless monitoring of material flows with trend monitoring
- Brand
- FEATURES & BENEFITS
- MAIN APPLICATIONS
- TECHNICAL SPECIFICATIONS
- TECHNICAL DATA
- MOUNTING & INSTALLATION
FEATURES & BENEFITS
- Absolutely insensitive against material deposits
- For any line diameter
- With adapter, usable up to 220 °C and 20 bar
- With ceramic mounting, usable up to 1000 °C
- Detection through all non-conductive walls
- Can also be supplied as compact device with integrated electronics
- Detection of material clogging and material standstill
MAIN APPLICATIONS
- Steel
- Food
- Biomass
- Cement
- Chemistry
- Coal plant
- Coating
- Incineration
- Minerals
- Wood
- Lime plant
- Energy
- Gypsum
- Power plant
- Foundry
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS | |
---|---|
Material to detect | Dust, powders or granulates |
Working principle | Microwave |
Process pressure | Max. 20 bar |
Process temperature | Up to +1000°C |
Mounting | 1 1/2 ” threat connection |
Type of Conveying | All |
Flow rates | No limit |
Pipe diameter/detection range | Up to 1200 mm |
ATEX rating | Category 3 |
Output | Relay, 4…20mA Trend |
TECHNICAL DATA
- Detects solid flows of all types for material movement
- Operates with no contact, using microwaves in a process in which the material movement is detected by using the Doppler effect
- If container walls, housings or pipelines are not metal, it is possible to measure from the outside
- Can also be used under difficult conditions such as high operating temperatures and pressures as well as in dust ex-zone 22 with the help of a process adapter
SENSOR TECHNICAL DATA | |
---|---|
Voltage | 12 V DC powered by transmitter |
Power consumption | Approx. 1.5 W |
Housing | Stainless steel 1.4571 |
Protection system | IP 65 |
Using in Ex-zones | Outside pipe: Cat. 3 D Inside pipe: Cat. 3 D (only with process adapter) |
Process temperature | -20… +80 °C (standard) -20… +220 °C (with process adapter) -20…+1000 °C (with ceramic flange) |
Ambient temperature | -20…+60 °C |
Working pressure | Max. 20 bar (with process adapter) |
Detection range | 0 – 2 m (dependent on application) |
Required material speed for detection | Min. 0.1 m/s |
Measuring frequency | K-Band 24.125 GHz; ± 100 MHz |
Transmitting power | Max. 5 mW |
Dimension FlowJam S | Housing: L 107 mm / Ø 52 mm Thread: L 30 mm / Ø G 1½” |
Dimension FlowJam S Ex | Housing: L 147 mm / Ø 60 mm Thread: L 15 mm / Ø G 1½” |
Cable gland | M16 (Ø 5-10 mm) |
Weight FlowJam S | Approx. 560 g |
Weight FlowJam S Ex | Approx. 850 g |
TRANSMITTER TECHNICAL DATA | |
---|---|
Power supply | 24 V DC ± 10 % |
Power consumption | Approx.. 3.5 W |
Relay contact | Max. rated load: 250 V AC Max. peak current: 6 A Max. rated load 230 V AC: 250 VA Max. breaking capacity DC1: 3/110/220 V: 3/0.35/0.2 A Min. switching load: 500 mW (10 V/5 mA) |
Analog output | 1 x 4 … 20 mA (0 … 20 mA) optional: load < 500 Ω (active) |
Fall-delay time | 250 ms…15 s (continuously adjustable) |
Weight | Approx. 172 g |
TECHNICAL DATA | ||||
---|---|---|---|---|
Pressure adapter | Temperature adapter | Food adapter | High temperature adapter | |
Material | Stainless steel 1.4571, POM diaphragm |
Stainless steel 1.4571, Tecapeek diaphragm |
Stainless steel 1.4571, Tecapeek GF30 diaphragm/td> |
Steel Ceramic diaphragm |
Temperature | -20…+80 °C | Max. +220 °C | Max. +220 °C | Max. 1000 °C |
Pressure | Max. 20 bar | Max. 20 bar | Max. 20 bar | Max. 40 bar |
Thread | G 1½ inch on both sides | G 1½ inch on both sides | G 1½ inch on both sides | G 1½ inch on both sides |
Wrench width | 55 mm | 55 mm | 55 mm | 17 mm |