It’s a great little sampler!
The GLS Sampler is designed for general purpose or priority pollutant sampling in municipal and industrial applications where a full-size sampler is too large. It collects composite samples, based on time or flow intervals, in 1- or 2.5-gallon glass or polyethylene bottles, or in 2-gallon disposable ProPak bags.
With GLS’s simplified programming, setup takes less than a minute. In the field, the operator simply calls up the program with two keystrokes, presses the “go” button – and the sampling routine begins. You can also key in an alternate program in the field, without losing your stored program.
- Brand
- STANDARD FEATURES
- APPLICATIONS
- SPECIFICATIONS
STANDARD FEATURES
Overall diameter is only 16.5 inches (42 cm), so GLS fits easily into manholes as small as 18 inches (46 cm), and also easily drops into most offset manholes.
Dry weight is less than 25 lbs (12 kg), the lightest sampler in the ISCO line.
Hinged handle makes one-handed carrying a breeze.
APPLICATIONS
Wastewater effluent
Stormwater monitoring
CSO
Permit compliance
Pretreatment compliance
SPECIFICATIONS
GLS Sampler
Size (Diam. x Height): | 16.5 x 26.5 inches (42 x 67 cm) |
---|---|
Weight: | 24.5 lbs (11.1 kg) (dry, less battery) |
Sample bottles: | 1.0 or 2.5 gallon polyethylene or glass container. |
Power Requirements: | 12 volts DC. (Supplied by battery or AC power converter.) |
Pump
Intake purge: | Purge before and after each sample. |
---|---|
Tubing life indicator: | Provides a message to change pump tubing. |
Intake suction tubing: | Length 3 to 99 ft. (1 to 30 m), Vinyl or Teflon® lined, ID 0.375 in. or 0.250 in |
Pump tubing life: | 2,000 samples |
Typical repeatability: | ±10 ml |
Maximum lift: | 26 ft. (7.9 m) |
Typical line velocity @ Head height: | 2.9 ft./s @ 3 ft; 2.5 ft./s @ 10 ft; 1.9 ft./s @ 15 ft. (0.76 m/s @ 0.9 m; 0.76 m/s @ 3.1 m; 0.58 m/s @ 4.6 m) |
Sample presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Operational Temperature: | 32° to 120°F (0° to 49°C) |
Controller
Enclosure: | NEMA 4X, 6 IP67 |
---|---|
Program storage: | 1 sampling program (in non-volatile ROM) |
Flowmeter signal input: | 5 to 15 volt DC pulse or 25 millisecond contact closure. |
Number of composite samples: | Up to 500 maximum |
Clock accuracy: | 1 minute per month, typical, for Real Time Clock |
Sampling modes: | Uniform time, flow. (Flow mode is controlled by external flow meter pulses.) |
Sample frequency: | 1 minute to 9,999 minutes, in 1 minute increments. 1 to 9,999 flow pulses. |
Sample volumes: | Programmable 10 to 9,990 ml in 1 ml increments |
Controller diagnostics: | Tests for RAM, ROM, pump, and display |