LAS5000XD In-Situ Cross Duct Laser (TDLS) Gas Analyzer

SKU: N/A

The In-Situ TDLS gas analyzer has been designed for meeting the requirements of a large range of CEMS and Process applications.

LAS 5000XD uses Tunable Diode Laser Spectroscopy (TDLS) and comes in various models for measuring parameters such as NH3 + H2O, HF, CO + CO2, O2, HCl + H2O, etc.
It combines robustness, fast response time (1 s) and high accuracy measurement in harsh environments (ready for Ex Zone II).

Key operator benefits of LAS 5000XD In-Situ laser gas analyzer:

  • No sampling system needed
  • No gas temperature influence
  • Gas matrix interference free
  • Calibration free measurement
  • FEATURES & BENEFITS
  • MAIN APPLICATIONS
  • TECHNICAL SPECIFICATIONS
  • TECHNICAL DATA
  • VIDEO

FEATURES & BENEFITS

KEY FEATURES

  • New Embedded ClearPath functionality
  • Highly sensitive and selective measurement
  • High signal-to-noise ratio
  • No measurement drift
  • Response time 1 s
  • Large dynamic range from ppm to %
  • Real-time communication between Transmitter (Tx) and Receiver (Rx)
  • Robust, ready for Ex Zone II (certification to come)

💡 CLEARPATH

  • Interference of relative humidity, O2 or CO2 is removed in purging areas.

Operator’s benefits:

  • No need for N2 or dry air purge
  • High accuracy of O2 measurement
  • High accuracy of H2O measurement
  • High accuracy of CO2 measurement

CUSTOMER BENEFITS

  • Low maintenance and cost of ownership
  • No need for N2 or dry air purge: Oil & dust free air instrument is enough
  • Process optimization leading to reduction of operating costs

MAIN APPLICATIONS

A WIDE RANGE OF APPLICATIONS FOR CEMS AND PROCESS

  • Ammonia slip control (DeNox)
  • Process and combustion control
  • HF emission control in aluminum plant
  • HCl/SO2 abatement control
  • Ethylene cracking furnace control
  • HCl level in semiconductor production
  • Ammonia concentration control in pet food, fertilizer plants, etc

TECHNICAL SPECIFICATIONS

MEASURABLE PARAMETERS
Pollutant Range
NH3 + H2O 0–10 ppm / 0–5000 ppm + 0–5% / 0–50%
HF 0–3 ppm / 0–500 ppm
CO ppm + H2O 0-50 ppm / 0-1% + 0-10% / 0-50%
CO% + H2O 0-1% / 0-100% + 0-10% / 0-50%
CO% + CO2 0-1% / 0-100% + 0-1% / 0-100%
CO2 + H2O 0-1% / 0-100% + 0-10% / 0-50%
O2 0-1%/ 0-100%
HCl + H2O* 0-10 ppm / 0-5000 ppm + 0-10% / 0-50% (*gas temperature must be above 150°C).
Other gases Available upon request: CH4, H2S, H2, NO…
TECHNICAL SPECIFICATIONS
Technology ADLAS (Advanced Detection Laser Absorption Spectroscopy)
• Optimized Opto-Mechanical Design
• High Speed Low-Drift Electronics
• Powerful Signal Processing and Algorithm
• Independent Spectroscopy Technique
Lower Detection Limit < 1% of FS
Response Time (0–90%) – Short 1 s
Lack of fit/Linearity ≤ ±1%
Flue Gas Temperature (°C max)
NH3 + H2O / HCl + H2O / HF
CO + H2O / O2 / CO + CO2
+400°C (Depends on the concentration range)
+1200°C (Depends on the concentration range)
Flue Gas Pressure 2 bars max (absolute)
Display on Tx 4 x 20 LCD
Communication Modbus RTU (RS485) / Ethernet (RJ45) – Web server
Power supply type + 24 V DC, ripple and noise 50 mV
Power consumption 15 W (warm-up)
< 15 W in standard use
Recommended T° (ambient) -20°C to +55°C
IP index Tx & Rx enclosures IP65
Flange specification requirement on stack DN50 PN16, 2’’ – 150 lbs, Class 150
Flange material SS 316 L
Air consumption
(main purge – necessary)
5-50 L/min (to adjust according to site conditions)
(dry and oil free, ISO 8573.1 Class 2-3)
Air consumption
(secondary purge – recommended)
2-3 L/min (dry and oil free, ISO 8573.1 Class 2-3)
Stack diameter compatibility From 0.5 to 20 m
Note – The technical specifications are defined in the following conditions: Gas temperature = 25°C / gas
pressure = 1013 mbar / pathlength = 100 cm / ambient temperature = 25 °C

TECHNICAL DATA

OPTIONS
Junction Box Analog I/O (2 x 4-20 mA/2 x 4-20 mA) – Digital Output (2 relays)
Thermal Shield Thickness: 20 mm (100°C<Tp<300°C) ; 40 mm (300°C<Tp<600°C) ; 60 mm (Tp above 600°C).
Audit Cell
Inline Cell
Alignment Tool
Weather protection covers

VIDEO

    More From Avensys

    More Services

    Our certified engineers and technicians can intervene from the initial consultation and planning stages, throughout the life of instruments and systems.
    Happy Professional Heavy Industry Engineer Worker Wearing Uniform, and Hard Hat in a Steel Factory. Smiling Industrial Specialist Standing in a Metal Construction Manufacture.

    Field & In House

    Develop customized monitoring plans that address client's unique needs...
    https://avensys.com/wp-content/uploads/2023/05/power-plant-1280x854.jpg

    Start up

    Start up & Commissioning is a critical phase in the life cycle of any project.
    https://avensys.com/wp-content/uploads/2023/05/integrated2500-1280x849.jpg

    Integrated Systems

    The benefits include improved performance, reduced costs, and increased reliability.
    https://avensys.com/wp-content/uploads/2023/05/Depositphotos_445297446_XL-1280x854.jpg

    Training

    We believe that product training is essential for both our employees and our clients.