MaxxFlow HTC Mass Flow Measurement for Dry Bulk Solids

SKU: MaxxFlow HTC

Contact-less and maintenance free measurement of high mass flow rates of dry bulk solids independent of pipe run

Electromagnetic flowmeter, designed to measure bulk material flows up to 300 t/h.
The meter has no mechanical parts in the flow, is 100 % dustproof and erosion free thanks to the ceramic inner pipe.

  • arbitrary mounting position (inclined/free fall)
  • low headroom required
  • easy to calibrate
Flow measurement from 10 t/h to 300 t/h

 

  • Brand
  • FEATURES & BENEFITS
  • MAIN APPLICATIONS
  • TECHNICAL SPECIFICATIONS
  • TECHNICAL DATA
  • MOUNTING & INSTALLATION
  • VIDEO

Brand

Envea SWR

FEATURES & BENEFITS

  • Most non-metallic solids can be measured
  • Can be installed on round pipes or ducts
  • No real upper limit of mass flow
  • Maximum pressure 10 bar
  • Dust tight
  • No flow restrictions to the process flow (wear resistant ceramic liner)
  • The mass flow measurement is independent of flow characteristics
  • Maximum temperature, 12O °C
  • Can be installed at an angle
  • Small footprint, 220 mm (DN 100), 290 mm (DN 150), 310 mm (DN 200)
  • No moving parts, hence no maintenance

MAIN APPLICATIONS

    • > For flow rates up to 300 t/h
    • > Low installation height
    • > Suitable in situations in which it was previously only possible to use complicated, inaccurate or expensive mechanical solutions (impact plates, measuring chutes)

    Installation independently of direction of line (vertical, inclined), but always after mechanical conveyor elements, in various industries:

  • Cement
  • Chemistry
  • Energy
  • Coal plant
  • Food
  • Minerals
  • Lime plant
  • Gypsum
MAIN APPLICATIONS
  • Mass-flow measurement of raw meal
  • Mass-flow measurement of potato starch in free fall prefiding chain conveyors
  • Mass-flow measurement of salt in free fall pre feeding chain conveyor
  • Mass-flow measurement of wood pellets in free fall
  • Flow mettering of grains

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
Material to measureDust, powders or granulates max grain size 30 mm
Working principleElectromagnetic
Process pressure1 bar
Process temperatureUp to +120°C
MountingFlange build-in
Type of ConveyingGravity, also declining pipes
Flow ratesUp to 300 t/h
Pipe diameterUp to 200 mm feeder outlet
Output4…20mA, Modbus, Profibus

TECHNICAL DATA

Use:

The MaxxFlow HTC is specially developed for the flow measurement of dry bulk solids during high-volume throughput. Due to its completely open profile and its low installation height, the MaxxFlow HTC is especially suitable in situation in which it was previously only possible to use complicated or expensive mechanical solutions, e. g. impact plates or measuring chutes.

The installation of the MaxxFlow HTC takes place independently of the direction of the line (vertical/inclined), but always after mechanical conveyor elements,
e. g. rotary feeder, screw conveyors, air slides or chain conveyors.

SENSOR TECHNICAL DATA
HousingSteel St 52, powder-coated
(optional stainless steel 1.4571)
NW 80/100/150/200 mm,
Flange according EN 1092-1 / PN10
DN 80: variable
Inner TypeAl2 O3-Ceramic
Operating temperatureSensor pipe: – 20 … + 120 °C
Sensor electronic: 0 … + 60 °C
Max. working pressure1 bar
Working frequency88 kHz
Transmitting powerMax. 2 mW
WeightDepend on diameter
Accuracy± 1 … 3 %
(based on end of measuring range
and calibrated material)
System accuracy± 0.04 %
TRANSMITTER TECHNICAL DATA
MSE 300-DR (DIN Rail)MSE 300-FH (field housing)
Power supply24 V DC ±10 %110 / 230 V AC 50 Hz
(optional 24 V DC)
Power consumption20 W / 24 VA
Protection typeIP 40 to EN 60 529IP 65 to EN 60 529/10.91
Ambient operating temperature-10 … +45 °C
Dimensions (W x H x D)23 x 90 x 118 mm258 x 237 x 174 mm
WeightApprox. 172 gApprox. 2.5 kg
Connection terminals cable
cross-section
0.2-2.5 mm2 [AWG 24-14]
Current output1 x 4 … 20 mA (0 … 20 mA),
load < 500 Ω (Active)
3 x 4 … 20 mA (0 … 20 mA),
load < 500 Ω (Active)
InterfaceRS 485 (ModBus RTU) / USB
Pulse outputOpen collector – max. 30 V, 20 mA
Relay contactMax. rated load:
250 V AC
Max. peak current:
6 A
Max. rated load 230 V AC:
250 VA
Max. breaking capacity DC1:
3/110/220 V: 3/0.35/0.2 A
Min. switching load:
500 mW (10 V / 5 mA)
Data backupFlash memory
DIN rail fastening
DIN 60715 TH35
Cable screw connectors
3 x M20 (4,5 – 13 mm Ø)

MOUNTING & INSTALLATION

A complete measuring station consists of these components:

• Measuring feeder for installation in the conveyor line
• Transmitter

The measuring feeder is available in sizes DN 100, DN 150 mm and DN 200 mm.
On request the components inlet path (between conveyor element and sensor) and gate valve (for calibration) can also be configured and supplied.

The transmitter is connected to the sensor using 4-wired, shielded cable.
The maximum distance between measuring feeder and transmitter is 300 m.

 

VIDEO

More From Avensys

More Services

Our certified engineers and technicians can intervene from the initial consultation and planning stages, throughout the life of instruments and systems.
Happy Professional Heavy Industry Engineer Worker Wearing Uniform, and Hard Hat in a Steel Factory. Smiling Industrial Specialist Standing in a Metal Construction Manufacture.

Field & In House

Develop customized monitoring plans that address client's unique needs...
https://avensys.com/wp-content/uploads/2023/05/power-plant-1280x854.jpg

Start up

Start up & Commissioning is a critical phase in the life cycle of any project.
https://avensys.com/wp-content/uploads/2023/05/integrated2500-1280x849.jpg

Integrated Systems

The benefits include improved performance, reduced costs, and increased reliability.
https://avensys.com/wp-content/uploads/2023/05/Depositphotos_445297446_XL-1280x854.jpg

Training

We believe that product training is essential for both our employees and our clients.
Email
Phone
+1-888.965-4700
Our Offices