Submerged probe accuracy unaffected by wind, steam, foam, turbulence or air temperature change
The probe on the Isco 720 is mounted at the bottom of the channel, and uses a differential pressure transducer to measure the level of the flow stream. The 6712 Sampler then converts this depth measurement into flow rate. The probe’s venting system automatically compensates for changes in atmospheric pressure to maintain accuracy. The 720 provides accurate measurement at sites where wind, steam, foam, turbulence or air temperature fluctuations exist. The probe is suitable for small channels, and accurately senses pressure even when covered with silt and sand.
Isco mounting rings make it easy to install the probe in round pipes, manhole inverts, and other open channels. And with the Isco Street Level Installation Tool, you can install your monitoring system from ground level, eliminating the costs and hazards of entering manholes. Most flumes are also available with an integral recess for mounting an Isco Submerged Probe.
- Brand
- STANDARD FEATURES
- MAIN APPLICATIONS
- SPECIFICATION
STANDARD FEATURES
-
Submerged probe accuracy unaffected by wind, steam, foam, turbulence or air temperature change
-
Built-in flow conversions for most applications, including weirs and flumes, Manning formula, data points, or equation for special situations.
-
During the program’s operation, current flow and level values are viewable on the sampler’s LCD display.
-
All flow data stored in the sampler is available for later retrieval, reporting, and graphing using Isco Flowlink software.
MAIN APPLICATIONS
-
Flow measurement where wind, steam, foam, or turbulence exist.
-
Triggering the 6712 sampler based on flow or level.
-
Collecting flow proportioned samples.
-
Treatment capacity analysis
-
Stormwater monitoring
-
Combined sewer overflow studies
-
Long-term river and stream gauging
SPECIFICATION
720 Submerged Probe Flow Module
Size (HxWxD): | 4.9 x 5.7 x 2.0 in (12.4 x 14.5 x 5.1 cm) |
---|---|
Weight: | 1.1 lbs (0.5 kg) |
Material: | Polystyrene |
Enclosure: | NEMA 4X, 6 IP67 |
Power: | 9 to 14V DC (provided by 6700 Series Sampler) |
Program Memory: | Non-volatile, programmable flash; can be updated via interrogator port on 6700 Series Sampler using a PC |
Operating Temperature: | 32° to 120°F (0° to 49°C) |
Storage Temperature: | 0° to 140°F (-18° to 60°C) |
Submerged probe
Dimensions: | 9.5 x 0.875 in (24.1 x 2.2 cm) |
---|---|
Cable: | Standard range probe – 25 ft x 0.3 in (7.6 m x 0.8 cm); Extended range probe – 50 ft x 0.3 in (15.2 m x 0.8 cm) |
Level Measurement Method: | Submerged pressure transducer mounted in the flow stream |
Transducer Type: | Differential linear integrated circuit pressure transducer |
Operating Temperature: | 32° to 160°F (0° to 71°C) |
Compensated Temperature: | 32° to 100°F (0° to 38°C) |
Materials: | Type 316 stainless steel, chlorinated polyvinyl chloride (CPVC); PVC Cable |
Level Measurement Range: | 0.1 to 10 ft (0.03 to 3.05 m) |
Maximum Allowable Level: | 20 ft (6.1 m) |
Level Measurement Accuracy (at 25°C (77°F) – Max error (±) for indicated level range)
0.1 to 5.0 ft (0.03 to 1.52 m): | ±0.01 ft (±0.003 m) |
---|---|
0.1 to 7.0 ft (0.03 to 2.13 m): | ±0.03 ft (±0.009 m) |
0.1 to 10 ft (0.03 to 3.05 m): | ±0.10 ft (±0.03 m) |
Temperature Coefficient (Max error per degree of temperature change over compensated range)
0.1 to 4.0 ft (0.03 to1.22m): | ±0.005ft/°F (±0.0027m/°C) |
---|---|
4.0 to 10 ft (1.22 to 3.05m): | ±0.007ft/°F (±0.0038m/°C) |