MP101M Automatic & Real-Time Suspended Particulate Monitor

SKU: MP101M

MP101M Beta gauge monitor with its optional OPM (Optical Particulate Monitor)

The standard Beta gauge measurement Method ISO 10473 of the MP101M analyzer allows, when used with the optical technology of the OPM module, the continuous and simultaneous measurement of fine dust.

 

The beta attenuation instrument is compliant with EN 16450 for PM10 and PM2.5 European Standards. QAL1 certified by the TÜV, the MP101M is also approved as Federal Equivalent Method (FEM) by US EPA for PM10 and PM2.5 continuous suspended particulate monitoring.

 

Ask us about this item

  • Brand
  • Features & Benefits
  • Main Applications
  • Technical Specifications
  • Options & Accessories
  • Principal of Operations

Brand

Envea Ambient

Features & Benefits

  • True volumetric air flow control with 3 atmospheric pressure and temperature sensors
  • Sampling flow-rate continuously regulated to the atmospheric temperature and pressure: reduces evaporation artefacts of volatile compounds (mandatory for PM2.5 according to EU regulations)
  • Automatic calibration of the real time optical module (OPM) to the reference measurement (ß gauge)
  • Flow calibration possible during the measurement
  • Built-in reference gauge for calibration: no need for factory re-calibration
  • Calibration screen for atmospheric pressure sensors
  • Regulated Sampling Tube (RST) compliant with CEN PM10 and US-EPA standard: sample not affected by seasonal or geographical factors and avoids evaporative losses of semi-volatile particles
  • Fibreglass tape with 3 years of autonomy of continuous sampling with daily cycles (1200 cycles)
  • Low activity C14 sealed flat source with analyzer lifetime duration
  • Rugged instrument, not sensitive to vibration, humidity, temperature…
  • New: On board web server compatible with any internet browser. ENVEA Connect™ user interface with on-line help for the display, configuration, maintenance, diagnostics or software updating of the analyser, remotely, from any PC, tablet or smartphone.

Main Applications

  • Ambient air quality monitoring
  • Indoor dust monitoring
  • Working places

Technical Specifications

MP101M TECHNICAL SPECIFICATIONS
Measured parameter PM10, PM2.5, PM1, TSP
Technology Beta Ray Attenuation
US-EPA Approval / QAL 1 Certification YES
Measurement ranges up to 10 000 μg/m3
Measurement units µg/m3
Lower Detectable Limit (2σ) 0.5 μg/m3 (24h average)
Sample flow rate 1 m³/h
Sampling pump External (vacuum pump)
Temperature range +5°C to 40°C
Data storage Unlimited
Included I/O LAN/USB/WIFI/AO
Weight (Kg) 15.2 (+pump: Picolino 4.6Kg / KNF 9.4Kg)
Dimensions mm (LxWxH) 360.5 x 483 x 266
Chassis 19″ Rack, 3U
Pressure and temperature compensation YES

Options & Accessories

  • OPM module for optical real-time measurement
  • US EPA and EU-CEN compliant sampling inlets
  • Temperature-regulated sampling tube (RST): 1 m, 1.5 m, 2 m, 2.75 m, compliant with CEN PM10 Directive
  • Max 2 ESTEL electronic boards with:
    – 4 independent analog inputs / outputs
    – 4 remote control inputs
    – 6 dry contacts outputs
  • External pump assembly: diaphragm (9.5kg), rotary vane (7kg)
  • Easy to install span calibration module for automatic and programmable calibrations
  • Field connection kit for leak and zero test (on RST tube)
  • Laboratory connection kit for leak and zero test (on MP101M)
  • Bead flowmeter for leak test
  • HEPA filter for zero test

Principal of Operations

The MP101M, based on the beta attenuation measurement technique, determines the particles concentration by measuring the amount of radiation that a sample, collected on a fiber tape, absorbs when exposed to a radioactive source.
Low energy beta rays are absorbed by collision of dust, whose number is proportional to density. Absorption is thus a function of the mass of the irradiated material, independently of its physico-chemical nature.
The OPM’s (Optical Particulate Monitor) principle is based on the measurement of the light scattered by the particles. A powerful algorithm is applied to continuously convert the signal into mass concentration.
Combination of both technologies provides simultaneously approved particulate measurement PLUS real-time indication of PM10, PM2.5 and PM1.
More From Avensys

More Services

Our certified engineers and technicians can intervene from the initial consultation and planning stages, throughout the life of instruments and systems.
Happy Professional Heavy Industry Engineer Worker Wearing Uniform, and Hard Hat in a Steel Factory. Smiling Industrial Specialist Standing in a Metal Construction Manufacture.

Field & In House

Develop customized monitoring plans that address client's unique needs...
https://avensys.com/wp-content/uploads/2023/05/power-plant-1280x854.jpg

Start up

Start up & Commissioning is a critical phase in the life cycle of any project.
https://avensys.com/wp-content/uploads/2023/05/integrated2500-1280x849.jpg

Integrated Systems

The benefits include improved performance, reduced costs, and increased reliability.
https://avensys.com/wp-content/uploads/2023/05/Depositphotos_445297446_XL-1280x854.jpg

Training

We believe that product training is essential for both our employees and our clients.