Continuously monitors particulate flow for signs of filter damage or broken filter bags. Compact and cost effective
The Dusty C has been specially developed to monitor clean sides after filters with high reliability and without time delay for filter breaks.
It can be used in metallic ducts in which dust particles will be detected in the gas flow. Its area of application begins at dust levels of 0.1 mg/m3.
Dusty C can be used in Ex zones (Dust zone 22 /Gas zone 2).
- Brand
- FEATURES & BENEFITS
- MAIN APPLICATIONS
- TECHNICAL SPECIFICATIONS
- TECHNICAL DATA
FEATURES & BENEFITS
- Detects all dust types
- Can be used in all purge gas and dust ducts
- Immediate detection of filter damages
- Simple commissioning (Plug & Play)
- Prevention of process-induced dust Ex zones
- Individual choice of alarm level
- Rapid and easy retrofitting
- 4 … 20 mA output at sensor
MAIN APPLICATIONS
- Aluminium
- Cement
- Chemistry
- Electronics
- Extraction
- Fertilizer
- Food
- Glass
- Granite
- Mills
- Products of carbon
- Quartz sand
- Wood
- Metal
- Building materials
- Power plant
- Surface purification
- Automotive
TECHNICAL SPECIFICATIONS
- Can be used in metallic ducts
- Operational range: starts at dust levels of 0.1 mg/m3
TECHNICAL DATA
SENSOR TECHNICAL DATA | |
---|---|
Measurement items | Solid particles in gas & dust ducts (flowstream) |
Measurement range | From 0.1 mg/m3 |
Process temperature | Max. 140 °C, optional 250 °C |
Ambient temperature | – 20 . . . + 60 °C |
Pressure | Max. 2 bar |
Flow velocity | Min. 3 m/s |
Humidity | 95 % RH (non-condensing) |
Measurement principle | Electrodynamic |
Attenuation time | 1 s |
Output signals | • Current output 4 … 20 mA • Relay output, either NC (break contact) or NO (make contact) |
Sensor rod | Total length: 260 mm Stainless steel part: approx. 194 mm |
Housing material | Aluminium |
Using in Ex-zones | Cat. 3 G/D (zone 2 gas / zone 22 dust) |
Protection category | IP65 |
Voltage supply | 24 ± 10 % V DC |
Rating | 1 W |
Electrical connection | Screw terminals / Connection chamber |
Installation | Via ½“ screw-in thread |
Weight | Approx. 1 kg |
More From Avensys
More Services
Our certified engineers and technicians can intervene from the initial consultation and planning stages, throughout the life of instruments and systems.