The Model 6200T Total Sulfur Analyzer utilizes proven UV fluorescent technology to continuously detect sulfur found in inert gas streams. An internal, quartz catalytic converter is employed to convert the sulfur, when mixed with scrubbed ambient air, into SO2 via higher temperature oxidation. An internal vacuum pump is employed to draw both the sample and the ambient air into the converter. The converted sample gas is fed to the fluorescence chamber where it is then exposed to ultraviolet radiation.
- Brand
- FEATURES
- SPECIFICATIONS
FEATURES
- Ranges of 0-50 ppb to 0-20,000 ppb TS (user-selectable), one or two ranges with auto-ranging capability (lower-ranges available with –U option)
- UV-Fluorescence technology
- High-temperature (1000°C) quartz converter with ceramic thermocouple ensures oxidation of all sulfur compounds
- Reliable Photo-Multiplier Tube (PMT) detector
- In-line particulate filter included
- Large, luminescent touch-screen display with easy-to-view characters
- Available with integral vacuum pump to draw sample or pump-less version
- Menu-driven functionality and numerous parameters detected with microprocessor-based functionality
- Front-panel accessible USB ports for firmware upgrades as standard
- Up to 4 analog outputs, 4-20 mA (isolated) or settable voltage type (0-100 mV, 0-1V, 0-5V, 0-10V)
- Ethernet and 2 x RS-232 digital outputs (optional USB, RS-485 or multidrop RS-232 available)
- 8 x opto-isolated digital outputs and 6 x opto-isolated digital inputs
- Power: 110 VAC or 220 VAC, 50 or 60 Hz (user to specify)
- Fittings, ¼” SS (6mm optional)
- Zero/span valves included as standard
- 19″ Rack mount with ears
SPECIFICATIONS
Ranges | Min: 0-50 ppb full scale Max: 0-20,000 ppb full scale (selectable, dual ranges and auto ranging supported) Analog Output Ranges: 10V, 5V, 1V, 0.1V (selectable) |
Noise | Zero: < 0.2 ppb (RMS) Span: < 0.5% of reading (RMS) above 50 ppb |
Drift | Zero: < 0.5 ppb/24 hours Span: < 0.5% of full scale/24 hours |
Timing | Lag Time: 20 seconds Rise/Fall Time: < 100 seconds to 95% |
Linearity | 1% of full scale |
Precision | 0.5% of reading above 50 ppb |
Flow Rate | 650 cm3/min ± 10% |
Power | 100V-120V, 220V-240V, 50/60 Hz |
Offset | ± 10% |
Temperature | 41° to 104°F (5° to 40°C) |
Dimensions | Analyzer: 7″H x 17″W x 23.5″D (17.8 x 43.2 x 59.7 cm) 35.7 lbs (16.2 kg) Converter: 7″H x 17″W x 22″D (17.8 x 43.2 x 55.9 cm) 24 lbs (10.8 kg) |