The 6400T Series analyzers uses a proven UV fluorescence principle coupled with state-of-the-art microprocessor technology to provide accurate and dependable measurements of low level SO2. The 6400T-H2S measures hydrogen sulfide (H2S) by incorporating a catalytic converter set at 600°F (315°C) to oxidize H2S into SO2 while leaving other more difficult to oxidize sulfurs unconverted. A switching mode allows analysis of both H2S and SO2 concurrently.
- Brand
- FEATURES
- SPECIFICATIONS
FEATURES
- Ranges of 0-50 ppb to 0-20 ppm SO2 (user-selectable), one or two ranges with auto-ranging capability
- UV-Fluorescence technology
- Reliable Photo-Multiplier Tube (PMT) detector
- In-line particulate filter included
- Large, luminescent touch-screen display with easy-to-view ranges with auto-ranging capability characters
- Integral vacuum pump to draw sample
- Menu-driven functionality and numerous parameters detected with microprocessor-based functionality
- Front-panel accessible USB ports for firmware upgrades as standard
- Up to 4 analog outputs, 4-20 mA (isolated) or settable voltage type (0-100 mV, 0-1V, 0-5V, 0-10V)
- Ethernet and 2 x RS-232 digital outputs (optional USB, RS-485 or multidrop RS-232 available)
- 8 x opto-isolated digital outputs and 6 x opto-isolated digital inputs
- Power: 110 VAC or 220 VAC, 50 or 60 Hz (user to specify)
- Fittings, ¼” SS (6mm optional)
- 19″ Rack mount with ears
SPECIFICATIONS
Detection | H2S and SO2 Analyzer |
Ranges | Min: 0-50 ppb H2S 0-50 ppb SO2 full scale Max: 0-10,000 ppb H2S 0-20,000 ppb SO2 full scale (user selectable, dual ranges and auto ranging supported) |
Noise | Zero: < 0.2 ppb (RMS) Span: < 0.5% of reading (RMS) above 50 ppb |
Drift | Zero: < 0.5 ppb of FS/24 hours Span: < 0.5% of FS/24 hours |
Timing | Lag: 20 seconds Rise/Fall: < 120 seconds to 95% FS |
Linearity | 1% of full scale |
Precision | 0.5% of reading above 50 ppb |
Flow Rate | 650 cm3/min ± 10% |
Power | 100-120V, 220V-240V, 50/60 Hz |
Offset | ± 10% |
I/O | Included: Up to 4 analog outputs: 4-20 mA (3 max) or settable DC voltage (0-10V, 0-5V, 0-1V, 0-0.1V) 1 x Ethernet: 10/100 Base-T 2 x RS-232 (300-115, 200 baud) 2 x USB device ports for firmware upgrades 8 x opto-isolated digital outputs 6 x opto-isolated digital inputs Optional: 1 x USB communications port 1 x RS-485 8 x analog inputs (0-10V, 12 bit) 4 x digital alarm outputs Multidrop RS-232 |
Temperature | 41° to 104°F (5° to 40°C) |
Dimensions | 7″H x 17″W x 23.5″D (17.8 x 43.2 x 59.7 cm) 41 lbs (18.3 kg) |
More From Avensys