The 6400T Series analyzers uses a proven UV fluorescence principle coupled with state-of-the-art microprocessor technology to provide accurate and dependable measurements of low level SO2. The 6400T-H2S measures hydrogen sulfide (H2S) by incorporating a catalytic convert​er set at 600°F (315°C) to oxidize H2S into SO2 while leaving other more difficult to oxidize sulfurs unconverted. A switching mode allows analysis of both H2S and SO2 concurrently.

  • Brand
  • FEATURES
  • SPECIFICATIONS

Brand

Teledyne Analytical TAI

FEATURES

  • Ranges of 0-50 ppb to 0-20 ppm SO2 (user-selectable), one or two ranges with auto-ranging capability
  • UV-Fluorescence technology
  • Reliable Photo-Multiplier Tube (PMT) detector
  • In-line particulate filter included
  • Large, luminescent touch-screen display with easy-to-view ranges with auto-ranging capability  characters
  • Integral vacuum pump to draw sample
  • Menu-driven functionality and numerous parameters detected with microprocessor-based functionality
  • Front-panel accessible USB ports for firmware upgrades as standard
  • Up to 4 analog outputs, 4-20 mA (isolated) or settable voltage type (0-100 mV, 0-1V, 0-5V, 0-10V)
  • Ethernet and 2 x RS-232 digital outputs (optional USB, RS-485 or multidrop RS-232 available)
  • 8 x opto-isolated digital outputs and 6 x opto-isolated digital inputs
  • Power: 110 VAC or 220 VAC, 50 or 60 Hz (user to specify)
  • Fittings, ¼” SS (6mm optional)
  • 19″ Rack mount with ears​

SPECIFICATIONS

​Detection ​H2S and SO2 Analyzer
​Ranges ​Min:    0-50 ppb H2S
0-50 ppb SO2 full scale
Max:   0-10,000 ppb H2S
0-20,000 ppb SO2 full scale
(user selectable, dual ranges and auto ​ranging supported)
​Noise ​Zero:    < 0.2 ppb (RMS)
Span:   < 0.5% of reading (RMS) above 50 ppb
​Drift ​Zero:    < 0.5 ppb of FS/24 hours
Span:   < 0.5% of FS/24 hours
​Timing ​Lag:           20 seconds
Rise/Fall:  < 120 seconds to 95% FS
​Linearity ​1% of full scale
​Precision ​0.5% of reading above 50 ppb
​Flow Rate ​650 cm3/min ± 10%
​Power ​100-120V, 220V-240V, 50/60 Hz
​Offset ​± 10%
​I/O ​Included:     Up to 4 analog outputs: 4-20 mA (3 max) or settable DC voltage (0-10V, 0-5V, 0-1V, 0-0.1V)
1 x Ethernet: 10/100 Base-T
2 x RS-232 (300-115, 200 baud)
2 x USB device ports for firmware upgrades
8 x opto-isolated digital outputs
6 x opto-isolated digital inputs
Optional:     1 x USB communications port
1 x RS-485
8 x analog inputs (0-10V, 12 bit)
4 x digital alarm outputs
Multidrop RS-232
​Temperature 41° to 104°F (5° to 40°C)​
​Dimensions ​​7″H x 17″W x 23.5″D
(17.8 x 43.2 x 59.7 cm)
41 lbs​ (18.3 kg)​
More From Avensys

More Services

Our certified engineers and technicians can intervene from the initial consultation and planning stages, throughout the life of instruments and systems.
Happy Professional Heavy Industry Engineer Worker Wearing Uniform, and Hard Hat in a Steel Factory. Smiling Industrial Specialist Standing in a Metal Construction Manufacture.

Field & In House

Develop customized monitoring plans that address client's unique needs...
https://avensys.com/wp-content/uploads/2023/05/power-plant-1280x854.jpg

Start up

Start up & Commissioning is a critical phase in the life cycle of any project.
https://avensys.com/wp-content/uploads/2023/05/integrated2500-1280x849.jpg

Integrated Systems

The benefits include improved performance, reduced costs, and increased reliability.
https://avensys.com/wp-content/uploads/2023/05/Depositphotos_445297446_XL-1280x854.jpg

Training

We believe that product training is essential for both our employees and our clients.