The 6400TSG series utilizes our field-proven ultraviolet (UV) fluorescence technology to continuously monitor the total sulfur content found in process gas and liquid feeds. UV-Fluorescence is a non-consuming method of detection, eliminating the hassles associated with replacing tape cartridges, and enables detection as low as 10 ppb, depending on application, with stable, reproducible results.
- Brand
- FEATURES
- SPECIFICATIONS
FEATURES
- Continuous analysis of total sulfur content, under gas-phase conditions, using the FCCM technology providing immediate, real-time TS readings for enhanced process control
- Superior flow and temperature control of liquid-phase samples via the QTCM Pyrolysis Technology ensuring high reliability and repeatability
- Excellent linearity for both gas and liquid phase conditions
- Wide range of analyzer diagnostic capabilities to continuously provide plant operators with system status conditions
- Sulfinert treated wetted parts to ensure trace levels of sulfur compounds are not absorbed into the pores of the tubing. Ensures accurate and quick response to process changes
- Wide dynamic detection capabilities from ppb up to % levels
- Easy-access, dual-door (front & rear) NEMA-4/4X system enclosure
- Multi-stream, sequencing capabilities with a single system providing reduced capital and installation costs
- Purged cabinet solutions for hazardous area installations with ambient temperature control devices designed-in for reliable field operation
- Ethernet connection allowing for remote control without having to defeat system purge
- Front panel, weather-proof N4 control switches allowing for local control without having to defeat system purge
SPECIFICATIONS
Detection Method | UV-Fluorescence |
Converter Method | Flame Combustion Converter Module (FCCM) |
Analysis | Continuous |
Compliance | Designed to meet requirements of ASTM D6667 |
Area Classification | Class 1, Div 1/Zone 1 and Div 2/Zone 2 versions with third-party approved purge available as standard |
Range | 0-200 ppb to percent levels total sulfur (TM) – specify at time of order |
Repeatability | ± 2% of full scale, optionally ± 1% |
Response Time | 90% of full scale in less than 100 seconds |
Temperature | 41° to 104°F (5° to 40°C) |
Noise | Less than 1% of full scale |
Drift | 2% of full scale per week, optionally 1% |
Supply Voltage | 110 or 220 VAC 50/60 Hz |
Outputs | 4-20 mADC (isolated) RS-232 Ethernet (optional) |
Flow Rate | 10 SCFH (5 LPM) standard |
Utility Gases | Air: < 1 ppm sulfur (500 ccm nom, 40 PSIG) Hydrogen: < 1 ppm sulfur (30 ccm, 40 PSIG) Nitrogen or air for purge (optional) Zero and span calibration gases |
Dimensions | 25″W x 72″H x 30″D (63.5 x 182.9 x 76.2 cm) |
More From Avensys
More Services
Our certified engineers and technicians can intervene from the initial consultation and planning stages, throughout the life of instruments and systems.