Microwave sensor for continuous moisture measurement in dry bulk solids, with flow detection and process temperature measurement
Sensors for continuous moisture measurement and installation on conveyor belts, screw feeder or hoppers.
Two types of sensor-technology to cover a wide range of applications. Both sensors penetrate the product for most reliable measurements.
Microwave based sensor for high resolution and accuracy.
- highly resistant to abrasion
- integrated temperature reading
- flow detection function
- Brand
- FEATURES & BENEFITS
- MAIN APPLICATIONS
- TECHNICAL SPECIFICATIONS
- TECHNICAL DATA
- MOUNTING & INSTALLATION
FEATURES & BENEFITS
- Moisture ranges 0 … 65 % (depending on material)
- Measurement accuracy 0.1 %
- Online moisture measurement
- Instant and accurate process/material temperature measurement from 0 °C to 120 °C
- Flow detection alarm
- Independent of the material colour
- Temperature-resistant up to 120 °C
- Recording of surface moisture and capillary moisture
- ATEX-certified
MAIN APPLICATIONS
- Cement
- Chemistry
- Asphalt
- Food
- Glass
- Grain
- Lime
- Minerals
- Steel
- Wood
- Foundry
- Construction materials
- Biomass
- Recycling
- Building materials
- Power plant
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS | |
---|---|
Material to measure | Dust, powder, granulates and other bulk solids |
Place to measure | Screw conveyor, belt conveyor, container, slide, dryer, mixer |
Working principle | Microwave |
Moisture range | 0 to 65% (depending on application) |
Material temperature | Max. 120°C |
Temperaure measurement | Included |
Mounting | Flange |
ATEX rating | Category 1 |
Output | 4…20mA, Modbus, Profibus |
Flow detection | Included |
TECHNICAL DATA
- Moisture ranges: 0 – 65 % (depending on material)
- Measurement accuracy: 0.1 %
- Temperatur resistant: up to 120°
- ATEX – certified
- Materials: alls types of dust, powder, granulates and other bulk solids
- Different mounting positions possible
SENSOR TECHNICAL DATA | |
---|---|
Housing | Stainless steel 1.4571 |
Sensor surface | Ceramic |
Ex-protection (optional) | Zone 20 (Dust), Zone 0 (Gas) |
Protection category | IP 67 according to EN 60529 |
Material ambient temperature | 0 … +80 °C, optional 120 °C |
Working pressure | Max. 10 bar |
Power consumption | 0.6 W |
Response time | 0.1 sec |
Weight | Approx. 1000 g |
Measuring range | 0 … 65 % residual moisture (depending on material) |
Temperature measurement | 0 … +120 °C ± 0,6 °C (typical) betw. 0 and +120 °C ± 1 °C (Max.) betw. 0 and +70 °C ± 2 °C (Max.) betw. 0 and +120 °C |
Flow Detection alarm | YES |
Accuracy | 0.1 % absolutely in the calibrated measuring range |
Connection cable | shielded cable 4-wired, 0.25 mm2 |
TRANSMITTER TECHNICAL DATA | ||||
---|---|---|---|---|
Transmitter (DIN Rail) | Transmitter (field housing) | |||
Power supply | 24 V DC ±10 % | 110 / 230 V AC 50 Hz (optional 24 V DC) |
||
Power consumption | 20 W / 24 VA | |||
Protection type | IP 40 to EN 60 529 | IP 65 to EN 60 52 910.91 | ||
Ambient operating temperature | -10 … +45 °C | |||
Dimensions (W x H x D) | 23 x 110 x 121 mm | 258 x 237 x 174 mm | ||
Weight | Approx. 190 g | Approx. 2.5 kg | ||
DIN rail fastening | DIN 60715 TH35 | / | ||
Interface | ModBus RTU (RS 485) / USB | RS 485 (ModBus RTU) / USB | ||
Cable screw connectors | / | 3 x M20 (4.5 – 13 mm Ø) | ||
Connection terminals cable cross-section |
0.2-2.5 mm2 [AWG 24-14] | |||
Current output | 2 x 4 … 20 mA (0 … 20 mA), load < 500 Ω |
3 x 4 … 20 mA (0 … 20 mA), load < 500 Ω |
||
Pulse output | Open Collector – max. 30 V, 20 mA | |||
Relay contact | Max. rated load: 250 V AC Max. peak current: 6 A Max. rated load 230 V AC: 250 VA Max. breaking capacity DC1: 3/110/220 V: 3/0.35/0.2 A Min. switching load: 500 mW (10 V / 5 mA) |
|||
Data backup | Flash memory |
MOUNTING & INSTALLATION
Flexible positioning Installation situations Container Conveyor belt Free fall pipe |