TÜV QAL1 and MCERTS Approved, Stand alone or networked system option Particulate CEM providing high quality emission measurement for dust concentrations from industrial processes

Having a 0–7.5 mg/m³ certification range, the QAL 360 sensor can be used at low or high dust levels meeting the tightened minimum emission limit value of 5 mg/m³ for Large Combustion Plant specified in the Industrial Emissions Directive.

Certified to 7.5 mg/m³

 

  • Brand
  • FEATURES & BENEFITS
  • MAIN APPLICATIONS
  • TECHNICAL SPECIFICATIONS
  • TECHNICAL DATA
  • APPROVALS & CERTIFICATIONS

Brand

Envea PCME Emission

FEATURES & BENEFITS

  • ProScatter Backscatter sensor technology with superior minimum detection <1 mg/m³
  • Certified to 7.5 mg/m³
  • Zero and Span (reference) checks available to ensure optimal instrument performance and compliant with QAL1
  • Automatic Contamination Check – fully interrogates the optical system
  • Purge Flow Fail Sensor option with inbuilt automatic optical shield activation
  • Flue Gas Blocker to protect Plant Engineers from harmful flue gases during maintenance

MAIN APPLICATIONS

  • Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
  • Non-condensing / dry flue gases
    • Typical Applications:
  • Incineration
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg TiO2 / Coating Powder)
  • Power Generation Plant (eg Coal/Biomass)

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
Measured parametersDust
TechnologyProScatter Backscatter
Measurement / Monitoring capability<0 – 500 mg/m³*
Stack / Duct diameter suitabilityup to 10m
Flue gas temperatureup to 400°C
BaghouseYES
Cartridge FilterYES
Ceramic Filter/
Coalescent Filter/
CycloneYES
Electrostatic Precipitator (ESP)YES
Wet Electrostatic Precipitator (WESP)/
Wet Scrubber/
Sensor variantsStainless Steel
Hastelloy® corrosion resistant
QA checksYES
*Application dependant

TECHNICAL DATA

TECHNICAL DATA
Measurement capability<0 – 500 mg/m3
Stack Temperature Ranges-20°C-250°C, up to 400°C option
Functionality and QA ChecksFunctionality and QA Checks
Contamination CheckAutomatic
Flue Gas BlockerYES
Networked systemOption
Enclosure Protection RatingIP65

APPROVALS & CERTIFICATIONS

logo-tuv-qal1-QAL360-0000053808_en

  • The measurement system was tested by TÜV Rheinland Energy GmbH
    in accordance with the European Standards EN 15267 Part 1, 2 and 3 and
    is QAL1 certified according to EN 14181
  • MCERTs certified
More From Avensys

More Services

Our certified engineers and technicians can intervene from the initial consultation and planning stages, throughout the life of instruments and systems.
Happy Professional Heavy Industry Engineer Worker Wearing Uniform, and Hard Hat in a Steel Factory. Smiling Industrial Specialist Standing in a Metal Construction Manufacture.

Field & In House

Develop customized monitoring plans that address client's unique needs...
https://avensys.com/wp-content/uploads/2023/05/power-plant-1280x854.jpg

Start up

Start up & Commissioning is a critical phase in the life cycle of any project.
https://avensys.com/wp-content/uploads/2023/05/integrated2500-1280x849.jpg

Integrated Systems

The benefits include improved performance, reduced costs, and increased reliability.
https://avensys.com/wp-content/uploads/2023/05/Depositphotos_445297446_XL-1280x854.jpg

Training

We believe that product training is essential for both our employees and our clients.
Email
Phone
+1-888.965-4700
Our Offices