TÜV QAL1 and MCERTS Approved, Stand alone or networked system option Particulate CEM providing high quality emission measurement for dust concentrations from industrial processes
Having a 0–7.5 mg/m³ certification range, the QAL 360 sensor can be used at low or high dust levels meeting the tightened minimum emission limit value of 5 mg/m³ for Large Combustion Plant specified in the Industrial Emissions Directive.
Certified to 7.5 mg/m³
- Brand
- FEATURES & BENEFITS
- MAIN APPLICATIONS
- TECHNICAL SPECIFICATIONS
- TECHNICAL DATA
- APPROVALS & CERTIFICATIONS
FEATURES & BENEFITS
- ProScatter™ Backscatter sensor technology with superior minimum detection <1 mg/m³
- Certified to 7.5 mg/m³
- Zero and Span (reference) checks available to ensure optimal instrument performance and compliant with QAL1
- Automatic Contamination Check – fully interrogates the optical system
- Purge Flow Fail Sensor option with inbuilt automatic optical shield activation
- Flue Gas Blocker to protect Plant Engineers from harmful flue gases during maintenance
MAIN APPLICATIONS
- Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
- Non-condensing / dry flue gases
-
- Typical Applications:
- Incineration
- Metals (eg Steel/Aluminium)
- Minerals (eg Cement/Gypsum)
- Chemicals (eg TiO2 / Coating Powder)
- Power Generation Plant (eg Coal/Biomass)
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS | |
---|---|
Measured parameters | Dust |
Technology | ProScatter™ Backscatter |
Measurement / Monitoring capability | <0 – 500 mg/m³* |
Stack / Duct diameter suitability | up to 10m |
Flue gas temperature | up to 400°C |
Baghouse | YES |
Cartridge Filter | YES |
Ceramic Filter | / |
Coalescent Filter | / |
Cyclone | YES |
Electrostatic Precipitator (ESP) | YES |
Wet Electrostatic Precipitator (WESP) | / |
Wet Scrubber | / |
Sensor variants | Stainless Steel Hastelloy® corrosion resistant |
QA checks | YES |
*Application dependant
TECHNICAL DATA
TECHNICAL DATA | |
---|---|
Measurement capability | <0 – 500 mg/m3 |
Stack Temperature Ranges | -20°C-250°C, up to 400°C option |
Functionality and QA Checks | Functionality and QA Checks |
Contamination Check | Automatic |
Flue Gas Blocker | YES |
Networked system | Option |
Enclosure Protection Rating | IP65 |