No matter how much gas will be produced, AwiDESULF monitors continuously and regulates itself.For biogas plants with a capacity of 100 / 200 Nm3/h
- Brand
- OVERVIEW
- SPECIFICATIONS
OVERVIEW
SPECIFICATIONS
MICROBIOLOGICAL DESULPHURISATION
GENERAL DATA | AWIDESULF 100 | AWIDESULF 200 |
Volume biogas//h1 3 3
OPERATION CONDITIONS | |
Ambient temperature | 5 – 40 °C |
Ambient humidity | 0 – 80 % relative humidity |
Protection type | IP 54 |
POWER SUPPLY | |
Operation voltage | 230 VAC |
Power consumption | ~ 130 W ~ 215 W |
Power supply | solenoid valve and compressor are powered by Awite gas analysis system |
PROCESS CONNECTION | |
Number of air supply points | 1 – 4 |
Connection point of air supply | flexible or solid plastic pipe 1“ and connection with G1“ external thread on customer side |
Pipe length1 | ≤ 100m |
PROCESS CONTROL2 | |
Automatic control of air supply using a combination of PI-controller and a major FuzzyLogic | |
Control range in automatic mode between 0 to 1 % oxygen, depending on the measured hydrogen sulfide concentration | |
Monitoring of the upper limit of 3 % of oxygen | |
DISPLAY AND OPERATION2 | |
Panel-PC | 7“ TFT touch panel/800×480 |
SOFTWARE FEATURES2 | |
Display of measurement history | graphic/tabular |
Extensive data storage | 4 GB microSD card |
SAFETY MECHANISM |
Non-return valve behind compressor
More From Avensys
More Services
Our certified engineers and technicians can intervene from the initial consultation and planning stages, throughout the life of instruments and systems.