No matter how much gas will be produced, AwiDESULF monitors continuously and regulates itself.For biogas plants with a capacity of 300 / 500 Nm3/h
- Brand
- OVERVIEW
- SPECIFICATIONS
OVERVIEW
SPECIFICATIONS
MICROBIOLOGICAL DESULPHURISATION
GENERAL DATA | AWIDESULF 3001 | AWIDESULF 5001 | AWIDESULF 10001 |
Volume biogas/h2 3 3 3
OPERATION CONDITIONS | |
Ambient temperature | 5 – 40 °C |
Ambient humidity | 0 – 80 % relative humidity |
Protection type | IP 55 |
POWER SUPPLY | |
Rated voltage | 220 – 240 VAC |
Rated power 50Hz / 60Hz | 0,37 kW / 0,37 kW 0,75 kW / 0,90 kW 1,50 kW / 1,80 kW |
Power supply | solenoid valves are powered by Awite gas analysis system the compressor is powered on-site |
PROCESS CONNECTION | |
Number of air supply points | 1 – 4 |
Connection point of air supply | flexible or solid plastic pipe 1“ and connection with G1“ external thread on customer side |
Pipe length2 | ≤ 100 m |
PROCESS CONTROL3 | |
Automatic control of air supply using a combination of PI-controller and a major FuzzyLogic | |
Control range in automatic mode between 0 to 1 % oxygen, de-
pending on the measured hydrogen sulfide concentration |
|
Monitoring of the upper limit of 3 % of oxygen | |
DISPLAY AND OPERATION3 | |
Panel-PC | 7“ TFT touch panel/800×480 |
SOFTWARE FEATURES3 | |
Display of measurement history | graphic/tabular |
Extensive data storage | 4 GB microSD card |
SAFETY MECHANISM | |
Non-return valve behind compressor |
Motor protection switch with feedback